logo
Good price  online

products details

Home > Products >
AC EV Charger
>
Universal Mounting Backplate Wall Column AC EV Charger 7kW Anti Fog Tempered Glass TPE

Universal Mounting Backplate Wall Column AC EV Charger 7kW Anti Fog Tempered Glass TPE

Brand Name: Mckee Charging Cube
MOQ: 1
Price: Negotiate
Packaging Details: Wooden case packaging
Payment Terms: L/C,T/T,D/A,D/P
Detail Information
Place of Origin:
Luoyang, China
Certification:
TUV, CE, FCC
Rated Power:
7 KW Single Phase, 11 KW And 22 KW Three Phase Options
Input Voltage:
85 V To 265 V AC Single Phase Wide Range
Maximum Current:
32 A Adjustable From 6 A
Connector:
Type 2 Socket, SAE J1772 With NACS Adapter, GBT Option
Mounting:
Universal Backplate For Wall, Column And Pole Mount
Front Panel:
Tempered Glass With Anti-fog Anti-condensation Coating
Charging Cable:
5 M Weather Resistant TPE Sheath
Ingress Protection:
IP54, IK08
Flame Retardancy:
UL94 V0
Metering:
Class B Energy Meter, MID Option
Communication:
OCPP 1.6J, OCPP 2.0.1, 4G, Ethernet, Wi Fi
Operating Temperature:
-30 C To +55 C
Highlight:

7kW AC EV Charger

,

Anti Fog Tempered Glass Charger

,

Wall Column Mounting Backplate Charger

Product Description

The Universal Mount AC EV Charger is planned for installation teams that have to deploy dozens of pedestals in a short window and for fleets that operate in cold climate basements. It arrives with a standard universal mounting backplate that supports both wall-mounted and column-mounted installation, so the crew completes every bay with one set of tools and one documented procedure, and no extra adapter accessory has to be ordered, stocked or reconciled on site. The tempered glass panel is treated for anti-fog and anti-condensation performance, which keeps the display readable at minus 30 degrees Celsius and in high humidity, so screens in northern winter underground garages no longer blur from temperature difference. The matched charging cable uses a weather resistant TPE sheath built to the same service life target as the main unit, which removes premature cable replacement from the total cost of ownership calculation.

Key Features
  • Universal mounting backplate: One standard plate accepts wall bracket, pedestal column and pole adapters without extra accessories, so construction teams deploy with unified tools and procedures, cut on-site material management complexity and reduce the number of part numbers held in the project warehouse.
  • Anti-fog tempered glass panel: A tempered glass front with hydrophobic anti-condensation coating keeps the reading surface clear when the ambient temperature swings fast, maintaining display readability at minus 30 degrees Celsius in humid underground garages and removing blurred screens caused by temperature difference.
  • Weather resistant TPE charging cable: The matched cable uses a TPE sheath rated to the same service life target as the charger body, resistant to UV, ozone, oil and low temperature embrittlement, which avoids premature cable replacement due to aging and lowers the total cost of ownership across the equipment lifecycle.
  • Single platform for global grids: An ultra-wide 85 V to 265 V single phase input range adapts natively to mainstream residential voltage standards in North America, Europe and Asia Pacific, so distributors plan one catalogue entry instead of several voltage variants.
  • Low maintenance architecture: Front accessible terminals, a pluggable controller board and OCPP remote diagnostics shorten each service visit, and the sealed glass front needs only a damp cloth to stay presentable.
  • Complete installation kit: Backplate, anchor bolts, cable gland, water tight connector boots and a printed torque chart ship in one carton, so the crew finishes a bay without a second trip to the van.
Applications

Residential compounds and apartment basements are the primary field, where a single backplate standard lets the electrical contractor install wall bays on the outer walls and column bays between parking rows with the same drill jig and the same torque setting. Northern climate garages benefit from the anti-fog glass, because the display stays readable when a warm car enters a cold humid space and condensation forms on colder surfaces. Distributors serving several regions use the wide 85 V to 265 V input to hold one stock keeping unit for households across North America, Europe and Asia Pacific instead of managing three voltage codes. Hotel and office parking operators choose the TPE cable version because the cable outlives the usual two year replacement cycle, which flattens the maintenance budget line.

Packaging and Quality Assurance

Each set is packed in a moulded EPE shell inside a five layer corrugated carton, with the mounting backplate, anchor bolts, cable gland and water tight connector boots in a labelled accessory tray, and the tempered glass face protected by a peelable film and a rigid honeycomb board. Every unit passes a dielectric strength test, earth continuity check, insulation resistance test at 500 V, a four hour burn in at rated load and a 200 cycle plug in test on the connector before packing. The anti-fog coating is verified in a climate chamber at minus 30 degrees Celsius and 95 percent relative humidity, and the TPE cable is tested for 10000 flex cycles at minus 25 degrees Celsius.

Technical Specifications
ParameterSpecification
ModelGAC-7U (Universal Mount Series)
Rated Output Power7 kW single phase, 11 kW and 22 kW three phase versions
Input Voltage85 V to 265 V AC single phase, 380 V three phase version
Maximum Output Current32 A adjustable from 6 A, 16 A version for single phase markets
Connector TypeIEC 62196 Type 2 socket, SAE J1772 with adapter, GBT option
Mounting BackplateUniversal plate for wall, column and pole mount without extra adapter
Front PanelTempered glass with anti-fog anti-condensation coating
Charging Cable5 m weather resistant TPE sheath, same service life design as unit
Enclosure ProtectionIP54, IK08 impact resistance
Flame RetardancyUL94 V0 housing material
Metering AccuracyClass B energy meter, MID option
Operating Temperature-30 C to +55 C, humidity up to 95 percent non condensing
StandardsIEC 61851-1, IEC 62196, EN 61851-21-2
Warranty24 months on unit, 36 months on the controller board